Before construction starts, establish who receives monitoring alerts and what they are expected to do. A phone message achieves little if it reaches somebody who is absent, does not recognise the measurement point or cannot contact the work crew.

Agree a practical notification chain

Provide a primary and backup contact and check that messages arrive. Establish what an alert contains: measurement point, time, recorded value and selected threshold. The recipient should be able to find the associated event without searching several systems.

An alert belongs to a particular configuration. Changes to thresholds or recipients need a record. Otherwise, similar events may receive different treatment without an explanation. Agree who is authorised to make those changes.

Examine the recording and the work

When a message arrives, follow the project’s agreed response procedure. The responsible person needs to compare the recording with the activity log and information from the site. Check the instrument position and operation if there is reason to question the data.

Record the action taken, who was contacted and whether the working method changed. An alert should lead to traceable follow-up, rather than simply being marked as read. Decisions about the work belong to the people responsible for the project, supported by the appropriate technical assessment.

Alert functions can assist follow-up, but they do not replace an agreement about responsibility. Contact us about monitoring with alerts to discuss recipients, reporting and response arrangements before the project starts.

What to check

  • Test the recipient list before construction starts.
  • Record changes to alert thresholds and recipients.
  • Keep a record of the response to each alert.